Astm C 94 Pdf Free



ASTM F 1072 – 94 pdf free download February 14, 2019 ASTM E Comments: 0. Standard Specification for Expanded-Metal Doors1. This standard is issued under the fixed designation F 1072; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. ASTM C 42 describes the testing procedure and explains how the results should be corrected fo r height-to-diameter ratio. The nominal core diameter should not be less than 2 in. (50 mm) with 3 in. (75 mm) being the preferred diameter for shotcrete. ASTM C 823 states when and how cores should be taken, and the required. Test methods (e.g. Acceptance criteria (e.g. ASTM E 186 severity level 2, or MSS SP-54-1995). Any other information that might contribute to the.

Standard Test Method for
Particle Size Analysis of Natural and Man-Made Riprap
Materials1

This standard is issued under the fixed designation D 5519; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.

click below Astm D 5519 – 94 (Reapproved 2001) pdf free download

Concrete Construction

Astm C 94 Pdf Free Download

ASTM C-94 Standard Specification for Ready-Mixed Concrete

Astm

Material should confirm to

Cement - C 150 or C 595

Aggregates - C 33 or C330 (light weight concrete)

Water - clear and apparently clean

Admixtures - C 260, C 494, C 618, C 989, C 1017.

Information needs for specification:

1. Size of course aggregate.

2. Slump at delivery

3. % of air-entrained.

4. Specify one of the following

A. Compressive strength at 28 days (lab cure sample)

B. Cement content (bags or lb/yard3) , Maximum allowable water content, admixtures.

C. Compressive strength at 28 days, Minimum cement content (bags or lb/yard3), admixtures.

5. Unit weight (for light weight concrete).

Mixing and Delivery:

Adding water:no water should be added.

Sampling: volume:2 ft3, after discharge 15% of concrete before 85% of discharge. Sample should be taken within 15 minute of elapse time.

Discharge time:discharge should be completed within 90 minutes.

Minimum tests for Strength, slump, and air entraining

1. One test for 150 cubic yard.

2. One test from each separate batch.

3. One for each class of concrete.

AstmAstm

ASTM specified method of testing and sampling

1. Compression test specimens - C 31

Astm C94 Pdf Free Download

2. Compression test - C 39

3. Yield, unit weight - C 138

4. Air entraining - C 138, C 173, or C 231.

5. Slump - C 143.

6. Sampling fresh concrete - C 172.

7. Temperature - C 1064.

Recommended total air-content for air-entrained concrete:

Maximum aggregate size

Exposure

condition

3/8'

(9.5mm)

½'

(12.5mm)

3/4'

(19mm)

1'

(25mm)

1-1/2'

(37.5mm)

2'

(50mm)

3'

(75mm)

Mild

4.5

4

3.5

3

2.5

2

1.5

Moderate

6

5.5

5

4.5

4.5

4

3.5

Server

7.5

7

6

6

5.5

5

4.5

Tolerance in slump

1. When specification specifies 'maximum' or 'not to exceed'

Specified slump

3' or less

more than 3'

Plus tolerance

0

0

Minimum tolerance

1-1/2' (38 mm)

2-1/2' (63 mm)

Astm C94 Free Pdf

2. When specification did not specifies 'maximum' or 'not to exceed'

Specified slump

Tolerance

2' (51 mm) or less

±½' (13 mm)

More than 2' through 4'

±1' (25 mm)

More than 4'

±1-1/2' (38 mm)